Pt100 Model M medium-temperature precision thermometer (-100 °C to 250 °C)

815,00 1.860,00 

Manufacturer: Klasmeier / eXacal Modell: Pt100M

Description

Precision resistance thermometer with thin metal sheath and extra small ceramic temperature detector. This eXacal thermometer is designed to measure radial and vertical temperature profiles.

Temperature range: -100 °C to 250 °C

small measurement uncertainties:
between 5 mK and 10 mK

fast measuring times due to thin metal sheath

gGood heat connection due to small temperature sensor

optimal for the measurement of vertical temperature gradients

This eXacal thermometer was developed to measure vertical and radial temperature profiles in calibration equipment as part of the measurement uncertainty. This is required in several guidelines such as DKD-R 5-4 “Calibration of block calibrators”, DKD-R 5-3 “Calibration of thermocouples” or DKD-R 5-1 “Calibration of resistance thermometers”. In addition, the thermometer is suitable for measuring and setting heating zones on calibration furnaces. Of course, the thermometer can also be used in general to measure temperatures accurately.

Nicht das richtige Produkt für Sie?

Calibration

eXacal thermometers are calibrated in our own DAkkS calibration laboratory. The DAkkS accreditation ensures that all calibrations are traceable to national and international standards.

The calibration of the eXacal resistance thermometers is performed at ITS-90 fixed points. It is also possible to perform calibrations according to the comparison method in calibration baths and calibration furnaces. The measurement uncertainty is calculated from many components. The largest components are reproducibility, ITS-90 characteristic, self-heating and hysteresis.

Measurement uncertainty

Small measurement uncertainties with DAkkS calibration certificate

Temperature fixed points from mercury triple point -38,8344 °C to tin freezing point 231,928 °C

Temperature rangeMethodMeasurement uncertainty
-38,8344 °C – 0,01 °CMercury to water5 mK
0,01 °C – 29,7646 °CWater to gallium6 mK
0,01 °C – 156,5985 °CWater to indium9 mK
0,01 °C – 231,928 °CWater to zinn10 mK
The specified measurement uncertainties correspond to k=2, include an ITS-90 characteristic curve and are given for the respective range

Additional information

Kalibrierung auswählen

inklusive DAkkS Kalibrierung, ohne DAkkS Kalibrierung

Technical Data

Modell Pt100M
Temperature range -100 °C to 250 °C
Nominal resistance Pt100 (100 Ohm)
Connection Four-wire
Connection cable Temperature resistant – EMF low strands from own production
Connection Bananaplugs
Sheath material Metal
Thermometerwire Platinum
Dimensions
Handle ø 20 mm x 100 mm
Diameter ø 4 mm
Length 400 mm
Connection cable 2 m
measurement resistor / temperature sensor
Length 6 mm
Recommended measuring current 1 mA
Self-heating 30 mK @ 1 mA at 29,7646 °C (Gallium melting point)

Ich habe die terms and conditions und privacy policy gelesen und bin damit einverstanden